The formula to calculate bathroom exhaust fan size reads as follows.
Commercial bathroom exhaust fan sizing.
50 cubic feet per minute cfm intermittent or 20 cfm continuous.
This means that a fan must have the ability to move 14 400 cubic feet of air in an hour.
This fan calculator is typically used to calculate the cfm or cubic feet per minute of air exchange that may be desired in a building.
The higher the bath fan rating the more air can be vented out of the bathroom which means less moisture and mold build up.
The illustration above demonstrates the use of a ceiling exhaust fan mounted in the rest room exhausting the stale air.
10ft 10ft 8ft 7 5 106 67 cfm.
Sizing and finding high quality low maintenance exhaust and air movement equipment can save money for agencies and business owners.
Therefore it should have a fan rated for at least 54 cfm.
Other options for bath fans include lights heaters and even humidity sensors.
That computes to 960 cubic feet of air in the room.
One pound per square inch is equivalent to 27 7 sp.
A large bathroom with a jetted tub a toilet and a shower a common configuration in new homes would need a 200 cfm ventilation fan such as the broan l200 ventilation fan available from.
This section discusses the minimum exhaust capacity of the exhaust fan.
Here s how we get this number.
The bath fan calculator is standard guide to help you find the minimum fan rating for your specific bathroom.
For example if your bathroom is 6 feet wide and 9 feet long its square footage is 54.
This exhaust air can be routed either to the roof using ductwork and a roof vent or to the side.
To determine the square footage of your bathroom multiply the length times the width.
A commercial restroom will require air to be changed 8 12 times an hour depending on the size of the facility and your local code.
The rule of thumb is that you need at least 1 cfm per square foot of room area.
Bathroom fan exhaust size calculator.
Fan static pressure is measured in inches of water gauge.
Commercial and industrial ventilation can be expensive to install or update and finding the right type and size of fan will keep companies and industries in compliance with codes and regulations.
Whether exhausting air or bringing fresh air into a structure the calculation produced should help to figure out the size of fan s required to accomplish the air exchanges needed.
The minimum requirements say that this air should be changed 15 times an hour.
Why your bathroom should have an exhausting vent fan bathroom venting fans are about more than just eliminating noxious odors.
You now need to multiply 960 x 15.
Static pressure in fan systems is typically less than 2 sp or 0 072 psi.
For a standard 10ft by 10 ft bathroom with an 8 ft ceiling you will need an exhaust fan capable of 106 67 cfm.
Continue shopping bath exhaust.